Product Description
Preview
Medical oxygen inhaler with humidifier bottle for cylinder CE ISO medical oxygen regulator medical equipment
It is mainly used in the oxygen supply system of medical center, for the oxygen inhalation of emergency oxygen supply and anoxic patients in medical units, and for the inhalation flow control device in scientific research institutions, industrial and so on.Oxygen inhaler flow accurate, easy to use, safe.It is a necessary instrument for oxygen treatment for patients in hospital emergency roomThe function of an oxygen inhaler is to provide a constant pressure and flow of oxygen for the patient to use.Bottle-inserted oxygen inhaler uses its own pressure reducing device to reduce the high pressure in the oxygen cylinder (15Mpa when full) to the low pressure suitable for human use (0.2~0.2Mpa), and then output to the human body after being wet with water.And the wall plug oxygen inhaler because the input pressure is 0.2~0.4Mpa, so there is no need to decompress, directly output to the human body.
Operation method:
1. Add distilled water to the humidifying cup, and the water level in the bottle should not be higher than the top waterline, but not lower than the bottom waterline.Do not use normal saline instead.
2. Insert oxygen inhaler terminal should be closed before the flow regulation switch socket, quick plug direction, and adjust the oxygen and oxygen to aim the quick plug socket terminal holes inserted, when they hear "click" sound and see oxygen terminal socket lock set of automatic sliding, quick plug and oxygen terminal socket is connected to lock.
3. Insert the oxygen suction tube into the oxygen delivery joint before supplying oxygen, and then turn the flow regulating switch in the counterclockwise direction to start the origin, so that the floating ball slowly rises (the calibration line aligned by the center of the floating ball is the flow reading, the unit is liters/min), and the oxygen supply can be adjusted according to the need.
4. During the oxygen supply process of the inhaler, if the water in the inhaler bottle is lower than the lower water line, turn off the flow regulating switch in time, unscrew the humidation bottle, add distilled water according to the requirements of the first paragraph of this article, and then screw the inhaler bottle, and continue to supply oxygen.
5. When the inhaler stops using, the inhaler air source should be closed;If the inhaler needs to be removed, the inhaler should be held by hand, and then removed (the unlocking method of different oxygen supply terminal socket should be explained by the installation unit). Then, the inhaler should be cleaned and disinfected in the water inside the bottle, and stored in a room without corrosion and well ventilated.
It is mainly used in the oxygen supply system of medical center, for the oxygen inhalation of emergency oxygen supply and anoxic patients in medical units, and for the inhalation flow control device in scientific research institutions, industrial and so on.Oxygen inhaler flow accurate, easy to use, safe.It is a necessary instrument for oxygen treatment for patients in hospital emergency roomThe function of an oxygen inhaler is to provide a constant pressure and flow of oxygen for the patient to use.Bottle-inserted oxygen inhaler uses its own pressure reducing device to reduce the high pressure in the oxygen cylinder (15Mpa when full) to the low pressure suitable for human use (0.2~0.2Mpa), and then output to the human body after being wet with water.And the wall plug oxygen inhaler because the input pressure is 0.2~0.4Mpa, so there is no need to decompress, directly output to the human body.
Operation method:
1. Add distilled water to the humidifying cup, and the water level in the bottle should not be higher than the top waterline, but not lower than the bottom waterline.Do not use normal saline instead.
2. Insert oxygen inhaler terminal should be closed before the flow regulation switch socket, quick plug direction, and adjust the oxygen and oxygen to aim the quick plug socket terminal holes inserted, when they hear "click" sound and see oxygen terminal socket lock set of automatic sliding, quick plug and oxygen terminal socket is connected to lock.
3. Insert the oxygen suction tube into the oxygen delivery joint before supplying oxygen, and then turn the flow regulating switch in the counterclockwise direction to start the origin, so that the floating ball slowly rises (the calibration line aligned by the center of the floating ball is the flow reading, the unit is liters/min), and the oxygen supply can be adjusted according to the need.
4. During the oxygen supply process of the inhaler, if the water in the inhaler bottle is lower than the lower water line, turn off the flow regulating switch in time, unscrew the humidation bottle, add distilled water according to the requirements of the first paragraph of this article, and then screw the inhaler bottle, and continue to supply oxygen.
5. When the inhaler stops using, the inhaler air source should be closed;If the inhaler needs to be removed, the inhaler should be held by hand, and then removed (the unlocking method of different oxygen supply terminal socket should be explained by the installation unit). Then, the inhaler should be cleaned and disinfected in the water inside the bottle, and stored in a room without corrosion and well ventilated.