Product






Preview
Basic Info.Product DescriptionCertifications
Basic Info.
Model NO. | LPO-60 |
Condition | New |
Gas Type | Oxygen |
Noise Level | Low |
Parts | Filters |
Purpose | Gas Separation |
Delivery | 40days After Down Payment |
Kind | Ldh Industry HP Series |
Purity | 95-99.5% |
Separation Way | Psa |
Oxygen Pressure | 4-150bar |
Material | Carbon Steel and Stainless Steel |
Installation | Skid or Containerized |
Usage | Oxygen |
Machine Size | Medium |
Transport Package | Wooden Case with Export Standard |
Specification | standard and customerized |
Trademark | LDH |
Origin | China |
HS Code | 841960 |
Production Capacity | 3000 |
Package Size | 250.00cm * 150.00cm * 220.00cm |
Package Gross Weight | 600.000kg |
Package Size | 250.00cm * 150.00cm * 220.00cm |
Package Gross Weight | 600.000kg |
Product Description
Product Description
Preview
Industrial cut welding 99.6% purity oxygen generator
PSA (Pressure Swing Adsorption) is an advanced gas separation technology, based on the physical adsorption of the internal surface in the adsorbent to gas molecules, separating the gas by the characteristics of absorbing to the quantity of different gas in general pressure. The CMS (Carbon Molecular Sieve) is a sorbent picked up from the air, used in separating Oxygen and Nitrogen molecular. The absorption quantity of CMS is greatly higher for Oxygen than Nitrogen under the same pressure.KEY
FeaturesLow Operating cost;Automatic operation;Produces oxygen from compressed air;Easy to install and maintain.Typical applications for
oxygen
generatorAquacultureTorchFish
tank
PSA (Pressure Swing Adsorption) is an advanced gas separation technology, based on the physical adsorption of the internal surface in the adsorbent to gas molecules, separating the gas by the characteristics of absorbing to the quantity of different gas in general pressure. The CMS (Carbon Molecular Sieve) is a sorbent picked up from the air, used in separating Oxygen and Nitrogen molecular. The absorption quantity of CMS is greatly higher for Oxygen than Nitrogen under the same pressure.KEY
FeaturesLow Operating cost;Automatic operation;Produces oxygen from compressed air;Easy to install and maintain.Typical applications for
oxygen
generatorAquacultureTorchFish
tank
Preview

Preview

Preview
Welding
Hospital
Main equipment for
oxygen
generatorAir compressorRefrigeration dryerAir bufferOxygen generatorOxygen buffer
Hospital
Main equipment for
oxygen
generatorAir compressorRefrigeration dryerAir bufferOxygen generatorOxygen buffer
Preview

Preview

Preview

Preview
Oxygen generator
Feature1.Unique CMS safeguard are used to lengthen the life of CMS;2.Nitrogen chain liberated air automatic system is used to guarantee the quality of nitrogen;3.Air Cylinder Pressure are used to avoid CMS chalking by the high speed air impact;4.Reasonable structural design are make sure the transport, lifting and installation easier;5.Easy to use, plug and play.Oxygen
generator
of production equipmentBevelling machineBending rollAutomatic welding machineAutomatic casing cutterAutomatic arc-submerging welder
Feature1.Unique CMS safeguard are used to lengthen the life of CMS;2.Nitrogen chain liberated air automatic system is used to guarantee the quality of nitrogen;3.Air Cylinder Pressure are used to avoid CMS chalking by the high speed air impact;4.Reasonable structural design are make sure the transport, lifting and installation easier;5.Easy to use, plug and play.Oxygen
generator
of production equipmentBevelling machineBending rollAutomatic welding machineAutomatic casing cutterAutomatic arc-submerging welder
Preview

Preview

Preview

Preview
Oxygen
generator
Performance guarantee and after-sale serviceAll equipment in the contract be designed and manufactured in accordance with current Chinese & professional standard and regulations;Warranty period: 12 months after formal running or 18 months after delivery, whichever occurs first;Afterwards, prompt maintenance service and spare parts will be available with charge.Documents and drawings provided by the seller shall be drawn in English version.
Oxygen generator
QA1. What is the difference between a VPSA oxygen generator and a PSA oxygen generator?The PSA oxygen generator is suitable for use under 300 cubic meters and has the characteristics of simple and convenient, movable.
VPSA oxygen generator is suitable for more than 300 cubic meters of use, the greater the gas volume, the lower the energy consumption.
2. What is the difference between a fish pond aerator and a fish pond oxygen generator?The aerator is a self-contained air pump that mixes 20% of the oxygen in the air into the water.The oxygen generator is dissolved in water by producing 90% pure oxygen.Merchants need to consider the choice of aerobics or oxygen generators based on the type of fry, increasing the oxygen production rate to increase the production cycle, and the total ratio of fish ponds.
generator
Performance guarantee and after-sale serviceAll equipment in the contract be designed and manufactured in accordance with current Chinese & professional standard and regulations;Warranty period: 12 months after formal running or 18 months after delivery, whichever occurs first;Afterwards, prompt maintenance service and spare parts will be available with charge.Documents and drawings provided by the seller shall be drawn in English version.
Oxygen generator
QA1. What is the difference between a VPSA oxygen generator and a PSA oxygen generator?The PSA oxygen generator is suitable for use under 300 cubic meters and has the characteristics of simple and convenient, movable.
VPSA oxygen generator is suitable for more than 300 cubic meters of use, the greater the gas volume, the lower the energy consumption.
2. What is the difference between a fish pond aerator and a fish pond oxygen generator?The aerator is a self-contained air pump that mixes 20% of the oxygen in the air into the water.The oxygen generator is dissolved in water by producing 90% pure oxygen.Merchants need to consider the choice of aerobics or oxygen generators based on the type of fry, increasing the oxygen production rate to increase the production cycle, and the total ratio of fish ponds.
Preview

Preview

Preview

Preview
3. What is the purity of the PSA oxygen generator?The purity of the general PSA oxygen generator is 90%-93%.Our company's PSA oxygen generator can reach 95%, 98%, up to 99+%.4. What should I pay attention to when using the oxygen generator for ozone?
Ozone supporting oxygen generators mainly need to select an oxygen generator with stable gas volume and purity to avoid ozone concentration and production due to instability.
5. How to maintain the PSA oxygen generatorThe daily maintenance of the oxygen generator is relatively simple:(1) The air compressor should be regularly maintained, air filter, oil, and oil should be replaced by the manufacturer at regular intervals according to the instructions.(2) The dryer should regularly check the pressure of the refrigerant to make it timely. The heat sink should be cleaned with compressed air every day. The filter element should be replaced regularly. The normal temperature is 8000H. It depends on the specific situation and pressure difference.(3) Open the air storage tank drain once a day and drain the condensate from the air.(4) Check the automatic drainer daily to avoid clogging and lose drainage. If it is blocked, open the manual valve slightly, close the self-discharge valve and then remove the automatic drainer to disassemble and clean. When cleaning the automatic drain, use soap to clean.(5) The oxygen generator mainly checks the working pressure of the adsorption tower, and records the purity and flow rate.
Ozone supporting oxygen generators mainly need to select an oxygen generator with stable gas volume and purity to avoid ozone concentration and production due to instability.
5. How to maintain the PSA oxygen generatorThe daily maintenance of the oxygen generator is relatively simple:(1) The air compressor should be regularly maintained, air filter, oil, and oil should be replaced by the manufacturer at regular intervals according to the instructions.(2) The dryer should regularly check the pressure of the refrigerant to make it timely. The heat sink should be cleaned with compressed air every day. The filter element should be replaced regularly. The normal temperature is 8000H. It depends on the specific situation and pressure difference.(3) Open the air storage tank drain once a day and drain the condensate from the air.(4) Check the automatic drainer daily to avoid clogging and lose drainage. If it is blocked, open the manual valve slightly, close the self-discharge valve and then remove the automatic drainer to disassemble and clean. When cleaning the automatic drain, use soap to clean.(5) The oxygen generator mainly checks the working pressure of the adsorption tower, and records the purity and flow rate.
Preview
Certifications
Name:ISO 9001



Preview
Industrial Cut Welding 99.6% Purity Oxygen Generator
$2000 ~ $99724.52
Chemical industry chain · natural gas production equipment and parts · Gas Purification Generator
Model NO.:LPO-60
Transport Package:Wooden Case with Export Standard
Origin:China


Less than 50 EmployeesScientific Research and Technology Services